UV

TuMag Timelines Reference Sheet

SOPHI

ar_4

Timestamp Action Commands Duration (s) Description Images Produced Expected outcome
00_00_00_00_000 Abort 00 120 Abort & reset 0
  • Stop all
  • Reset FG
00_00_01_00_000 Ping 99 0 Ping for timestamping 0
  • Pong
00_00_02_00_000 Initial Settings 01 5 Settings for ROI, Gain & Exposure time 0
  • Changes in the cameras parameters
00_00_03_10_000 Obs Mod 0s + 2.02 11 44.2 Repetition of 5000 modes 0s+2.02 12/cam + 32/cam
  • Thumbnails arriving
  • Voltage changes from -3575V to -80V (Mode 0s) and +1730V to +2885V (Mode 2)
  • Images obatined
00_01_40_20_000 Stop Observation 97 30 Stops observation and empties queue 0
  • Stop current observation
00_01_40_50_000 Thumbnail Mg 51 1 Observation in Mg center for thumbnailing 1/cam
  • Thumbnails
  • Voltage to -2245V
  • Images
00_01_41_01_000 Abort 00 120 Abort & reset 0
  • Stop all
  • Reset FG
00_01_42_03_000 Initial Settings 01 5 Settings for ROI, Gain & Exposure time 0
  • Changes in the cameras parameters
00_01_42_13_000 Darks 31 139.3 Acquisition of darks 1/cam * 50
  • Thumbnails
  • HVPS at 0V
  • Images
00_01_47_21_000 Phase Diversity 33 28.8 PD measurements for 5250.2+Mg filters 40/cam * 2 (PD/F4) * 2
  • Thumbnails
  • HVPS to +2880V
  • FW to 5250.2 + PD
  • FW to 5250.2 + F4
  • HVPS to -80V
  • FW to 517 + PD
  • FW to 517 + F4
  • Images
00_01_48_32_000 Obs Mod 1 54 35.7 One mode 1 for Straylight 40/cam
  • Thumbnails arriving
  • Voltage changes in negative (Mode 1)
  • Images obatined
00_01_54_02_000 Linear polarizer for 3 lines TUMAG with LCVR set 34 19.4 Linear polarizer measurements for the 3 prefilters 4/cam * 3
  • Thumbnails
  • FW to PL, 5250.2
  • HVPS to +2880V
  • FW to 517
  • HVPS to -80V
  • FW to 5250.6
  • HVPS to -1750V
  • HVPS to 0V
  • Images
00_01_54_32_000 Micropolarizers for 3 lines TUMAG with LCVR set 35 19.4 Micropolarizer measurements for the 3 prefilters 4/cam * 3
  • Thumbnails
  • FW to MP, 5250.2
  • HVPS to +2880V
  • FW to 517
  • HVPS to -80V
  • FW to 5250.6
  • HVPS to -1750V
  • HVPS to 0V
  • Images
00_01_55_02_000 Pinholes 36 11.4 Pinhole measurements in 3 filters 1/cam * 3
  • Thumbnails
  • FW to PH, 5250.6
  • HVPS to -1750V
  • FW to 517
  • HVPS to -80V
  • FW to 5250.2
  • HVPS to +2880V
  • HVPS to 0V
  • Images
00_01_55_32_000 Flatfields Obs0s 40 257.2 Flat field observations for mode 0s (5 rep. obs, 4 lambda repeat) 12/cam * 4 lam_rep * 5 rep
  • Thumbnails
  • FW to 517
  • HVPS from -3580V to -80V
  • Images
  • HVPS to 0V
00_02_00_30_000 Flatfields Obs2.02 38 498.5 Flat field observations for mode 2.02 (5 rep. obs, 4 lambda repeat) 32/cam * 4 lam_rep * 5 rep
  • Thumbnails
  • FW to 5250.2
  • HVPS from +1729V to +2885V
  • Images
  • HVPS to 0V
00_02_12_32_000 Stop Observation 97 30 Stops observation and empties queue 0
  • Stop current observation
00_02_13_02_000 Thumbnail Mg 51 1 Observation in Mg center for thumbnailing 1/cam
  • Thumbnails
  • Voltage to -2245V
  • Images
00_02_13_07_000 Ping 99 0 Ping for timestamping 0
  • Pong
00_02_13_17_000 Ping 99 0 Ping for timestamping 0
  • Pong
00_02_13_22_000 Ping 99 0 Ping for timestamping 0
  • Pong
Universitat de Valencia 2022