UV

TuMag Timelines Reference Sheet

SOPHI

ew_1

Timestamp Action Commands Description Images Produced Expected outcome
00_00_00_00_000 Abort 00 Abort & reset 0
  • Stop all
  • Reset FG
00_00_02_40_000 Initial Settings 01 Settings for ROI, Gain & Exposure time 0
  • Changes in the cameras parameters
00_00_04_50_000 Ping 99 Ping for timestamping 0
  • Pong
00_00_04_55_000 Prefilter scan 32 Scanning voltage range for the Mg+5250.2 filters 35/cam * 2 rep * 2
  • Thumbnails?
  • HVPS to -100V
  • FW to 517
  • HVPS from -100V to -3500V
  • HVPS from -3500 to -100V
  • HVPS to +100V
  • FW to 5250.2
  • HVPS from +100 to +3500V
  • HVPS from +3500V to +100V
  • HVPS to 0V
  • Images
00_00_07_05_000 Ping 99 Ping for timestamping 0
  • Pong
00_00_08_10_000 Obs Mod 1 + 2.02 15 Repetition of 5000 modes 1+2.02 40/cam + 32/cam
  • Thumbnails arriving
  • Voltage changes from -3250V to -80V (Mode 1) and +1730V to +2885V (Mode 2)
  • Images obatined
00_00_18_25_000 Stop Observation 97 Stops observation and empties queue 0
  • Stop current observation
00_00_18_55_000 Set HVPS to 0V 96 Sets HVPS to 0V 0
  • Voltage to 0V
00_00_19_00_000 Ping 99 Ping for timestamping 0
  • Pong
00_00_19_05_000 Ping 99 Ping for timestamping 0
  • Pong
Universitat de Valencia 2022