University of València COVID Scientific and Technological Offer COVID Scientific and Technological Offer Logo del portal

400MHz NMR spectrometer for liquid samples
  • Small molecule structure elucidation: elucidation of connectivity, stereochemical configuration and conformation.
  • Structural characterisation of nanoparticles and their interactions with substrates.
  • Mobility studies and molecular dynamics.
  • Monitoring of chemical processes: kinetics.
  • Determination of association and molecular interaction processes.
  • Studies at variable temperatures.
  • Observation of a wide variety of magnetic cores: 19F, 195Pt, 133Cs, 11B, 31P, 6Li, 29Si, etc.
Cell Culture laboratory

Cell Culture laboratory of Biological Containment Level 2 (BCL2). It has several rooms: Cell Lines Room, Primary Cultures Room, Hypoxia Room and Viral Vectors Room (BCL2+), with 10 biosafety cabinets, 6 incubators and all the necessary equipment to work with eukaryotic cell cultures.

Prepared and controlled by technicians so the user just focuses on his experiment.

Cell Separator Flow Cytometer ARIA FUSION

Cell Separator equipped with 6 lasers, biosafety cabinet and aerosol extraction. It allows, firstly, the rapid measurement of morphological and functional parameters of a large number of individual cells suspended in liquid medium. For this, cells are initially labelled with fluorochrome-conjugated antibodies, or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.

In addition, after analysis, it is possible to separate and collect subpopulations of interest from the sample for further studies.

Cytometry laboratory

Fully equipped laboratory for sample preparation, acquisition, separation and analysis by flow cytometry.

Flow Cytometer Analyser FORTESSA

A 5-laser analysing cytometer for rapid measurement of morphological and functional parameters of large numbers of single cells suspended in a liquid medium. For this purpose, cells are initially labelled with fluorochrome-conjugated antibodies or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.

Flow Cytometer Analyser VERSE

A three-laser analysing cytometer for rapid measurement of morphological and functional parameters of large numbers of single cells suspended in liquid medium. For this purpose, cells are initially labelled with fluorochrome-conjugated antibodies or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.

Flow cytometer analyser - BD LSR Fortessa X-20

Equipment that determines and quantifies the fluorescence of fluorescent probes attached to different parts of both eukaryotic and prokaryotic cells, organelles, proteins. The emitted fluorescence is collected on different filters limited to a certain wavelength. Fluorescence quantification is associated with the cell parameter being measured, generating quantitative results such as fluorescence intensity, percentage of cell populations, cell count/ML.

Flow cytometer analyzer - BD FACSVERSE

Equipment that determines and quantifies the fluorescence of fluorescent probes attached to different parts of both eukaryotic and prokaryotic cells, organelles, proteins. The emitted fluorescence is collected on different filters limited to a certain wavelength. Fluorescence quantification is associated with the cell parameter being measured, generating quantitative results such as fluorescence intensity, percentage of cell populations, cell count/ML.

Microultracentrifuge

Ultracentrifuge for small volumes with 3 rotors: S55A2, S50A and swing-out rotor S52ST.

NCB2+ room for cell cultures

Room located inside the Cell Culture laboratory (NCB2), with its own equipment and higher level work protocols. Designed to work with viral vectors, GMOs or level 2 biological agents that require greater security.

Separating flow cytometer

Equipment that determines and quantifies the fluorescence of fluorescent probes attached to different parts of both eukaryotic and prokaryotic cells, organelles, proteins. The emitted fluorescence is collected on different filters limited to a certain wavelength. Fluorescence quantification is associated with the cell parameter being measured, generating quantitative results such as fluorescence intensity, percentage of cell populations, cell count/ML.

The equipment has a cell separation system allowing the physical separation of a given population with different levels of purity. It allows separation under sterile conditions.