Autoclave steam steriliser, 890 litres, double door, for the deactivation of biological waste as well as the substrate fumigation prior to its use. The sterilisation is done with pressure saturated water steam, functioning according to the process of fractionated vacuum.
Determination of the cellular fatty acid composition of microbial strains using gas chromatography.
Mycotoxin production from fungi typified in selected foods. Online simulation of intestinal digestion.
Cell Culture laboratory of Biological Containment Level 2 (BCL2). It has several rooms: Cell Lines Room, Primary Cultures Room, Hypoxia Room and Viral Vectors Room (BCL2+), with 10 biosafety cabinets, 6 incubators and all the necessary equipment to work with eukaryotic cell cultures.
Prepared and controlled by technicians so the user just focuses on his experiment.
Cell Separator equipped with 6 lasers, biosafety cabinet and aerosol extraction. It allows, firstly, the rapid measurement of morphological and functional parameters of a large number of individual cells suspended in liquid medium. For this, cells are initially labelled with fluorochrome-conjugated antibodies, or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.
In addition, after analysis, it is possible to separate and collect subpopulations of interest from the sample for further studies.
These are chambers with adjustable temperature and photoperiod. They are used for the growth of plants in controlled conditions. There are three of these chambers and two chambers that also have humidity control.
PCR oligos pairs amplifying genes or parts of genes of S. cerevisiae.
Cryopreservation room belonging to the Cell Culture laboratory for the storage and management of frozen samples from users and the section's cell bank.
Storage service for biological material under controlled conditions.
Fully equipped laboratory for sample preparation, acquisition, separation and analysis by flow cytometry.
Genetic analysis with high-performance servers, server-attached computers, bioinformatics software, development of working algorithms.
Open cultivation chamber for the growth and development of plants, completely shut off from the exterior and with precise control over the temperature, humidity, CO2 and radiation (max 300 μmoles/m2s per level) with the latest generation of white light LED tubes, with a focused spectrum for plant cultivation, AR 12.
Its internal dimensions are 2040 x 2010 x 3210 mm (height x width x depth).
Open cultivation chamber for the growth and development of plants, completely shut off from the exterior and with precise control over the temperature, humidity, CO2 and radiation (max 600 μmoles/m2s per level) with the latest generation of white light LED tubes, with a focused spectrum for plant cultivation, AR 12.
Its internal dimensions are 2040 x 2010 x 3210 mm (height x width x depth).
A 5-laser analysing cytometer for rapid measurement of morphological and functional parameters of large numbers of single cells suspended in a liquid medium. For this purpose, cells are initially labelled with fluorochrome-conjugated antibodies or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.
A three-laser analysing cytometer for rapid measurement of morphological and functional parameters of large numbers of single cells suspended in liquid medium. For this purpose, cells are initially labelled with fluorochrome-conjugated antibodies or fluorescent probes that bind to proteins located on the cell surface or inside the cell. The scattered light and fluorescence emitted by the markers as the cells are passed one by one through the different lasers allows simultaneous measurement of structural features and various parameters in each of these cells.
Qualitative and quantitative analysis of microbial populations by flow cytometry.
Gas chromatography analysis – triple quadrupole tandem mass spectrometry (MS/MS QqQ) of micro-pollutants in food.
Servers and software for spatially explicit cataloguing and integration of environmental information.
Venlo greenhouse cabin with biological containment level 1 (NCB1), with control of temperature, relative humidity, CO₂, lighting and irrigation through the Ridder Multima system for regulation, and climate and irrigation control.
Venlo greenhouse cabin with biological containment level 1 (NCB1), with control of temperature, relative humidity, CO₂, lighting and irrigation through the Ridder Multima system for regulation, and climate and irrigation control.
Water and sediment analysis laboratory.
Room located inside the Cell Culture laboratory (BCL2) composed of a closed Hypoxia Station and necessary equipment for the maintenance of the cultures. The closed station allows a precise control of the percentage of hypoxia and/or hyperoxia, even at extreme values, keeping the culture conditions constant at all times, both during its handling and within the incubators. All of this ensures reproducible data.
Equipment that quantitatively determines the concentrations of one, several or many substances in a biological (serum, plasma, tissue or urine), food or environmental sample. This is achieved by chromatographic separation of the compounds present in the matrix to be studied, either by liquid chromatography or gas chromatography and their subsequent nebulisation with fragmentation to detect the components according to their molecular weight.
Chamber that allows experimentation with large aquariums and plant cultures.
Liquid chromatography analysis accompanied by the detection in time of flight of bioactive compounds present in food.
Metabolomics, peptidomics and proteomics analysis.
Macrophyte live cultures resource.
Technique that allows the lyophilisation of biological material.
Gas accumulation chambers and tubes for experimental measurements, various CO₂ and CH4 measurement systems (absorption spectroscopy, infrared detection -IRGA, semi-conduction).
Microbial characterisation using several approaches.
Microbial identification by essential gene sequencing.
The MALDI-TOF MS technique allows obtaining the characteristic protein profile of a microbial strain from the analysis of its ribosomal proteins, mainly.
- Deposit of strains of archaea, bacteria, filamentous fungi and yeasts up to risk group 3* according to the definition of Royal Decree 664/1997 of 12 May 1997.
- Deposit of phages of microbial strains up to risk group 2 according to the definition of Royal Decree 664/1997 of 12 May 1997.
The CECT has a public catalogue that includes more than 8000 strains of bacteria, archaea, filamentous fungi and yeasts. It also has the Mengovirus vMCO and will soon incorporate some phage strains.
Research optical and fluorescence microscopes and stereo microscopes.
Ultracentrifuge for small volumes with 3 rotors: S55A2, S50A and swing-out rotor S52ST.
Molecular biology tools.
Room located inside the Cell Culture laboratory (NCB2), with its own equipment and higher level work protocols. Designed to work with viral vectors, GMOs or level 2 biological agents that require greater security.
Collection of probes for the manufacture of macroarrays. Macroarrays on nylon support with 5400 probes for S. cerevisiae genes.
Collection of samples and cultures of the different species of Iberian inland waters.
Equipment for the manufacture of density gradients and their subsequent fractionation used in the study of polysome profiling in cell extracts.
DNA extraction, whole genome sequencing (WGS), assembling, determination of quality parameters, genomic analysis...
BioGrid II is a robot for the fabrication of macroarryas on nylon support or for the copying of collections of microorganism strains deposited on microtitre plates.
High-precision spectrofluorometer.
Standard greenhouse cabin type "venlo", with control of temperature, relative humidity, CO₂, lighting and irrigation through the Ridder Multima system for regulation, and climate and irrigation control.
The UV Statistics Unit works with experts in the use of computer equipment and specific software. The main software used for data analysis is the free R Software.
Studies of toxic substances in cell cultures and experimental animals.
Collection of plasmids with different yeast genes.
Collections of wild-type and mutant strains of S. cerevisiae, S. pombe and C. albicans and E. coli transformed with recombinant plasmids.
In IDOCAL laboratory. Ability to measure physiological reactions of the individual (dermal response, heartbeat, sweating, etc.) to the presentation of various stimuli (brands, packaging, advertisements, etc.), in order to measure their effectiveness.